Troubleshooting Soku Minute Mattress deployment: structured guide for smooth operations

Introduction

Even with a robust and intuitive system, practical challenges can arise during large-scale deployment of Soku Minute Mattress. This structured guide helps your team recognise, resolve and prevent the most common issues-so that the operation remains efficient, safe and stress-free.

Most Common Issues and Their Solutions

Issue Possible Cause Solution
Air seal not strong enough Temperature too low or speed to high
  • Increase inflator temperature gradually
  • Decrease speed
  • Test after each adjustment
Seal overheated, edge loosens Temperature set too high or speed to low
  • Lower inflator temperature step by step
  • Increase speed
  • Test after each adjustment
Foil not feeding through Operator forgot to lock foil on the inflator feed.
  • Lock the foil feed with the lever before starting
Inflator does not start Power supply issue or safety switch engaged
  • Check power connection and ensure at least 600W available
  • Press ‘R’ (reset), then ‘Start’
Foil jams at inflator input Obstruction, debris, or misalignment
  • Open foil cover and remove jammed foil
  • Check for debris and clear carefully
  • Reinsert foil, ensure correct alignment, and restart
Teflon bands worn out Normal wear from use
  • Turn off inflator, open guide, and replace bands with spares
  • Contact supplier for additional spares if needed

Step-by-Step Troubleshooting

1. Temperature and Sealing Adjustments

  • Check inflator seal temperature and adjust gradually as needed.
  • Increase or decrease airflow to optimize seal strength and air pressure.
  • Always test after each change to ensure optimal results.

2. Resetting the Inflator

  • Press the ‘R’ (reset) button, then ‘Start’ as indicated on the machine and stickers.

3. Power Supply Checks

  • Ensure a stable power source with at least 600W output, especially at startup.
  • Test the inflator on the intended power supply before large deployments.

4. Resolving Foil Jams

  • Open the foil cover and carefully remove any jammed foil or debris.
  • Use the provided blade with caution if needed.
  • Reinsert the foil and ensure it feeds smoothly before restarting.

5. Replacing Worn Teflon Bands

  • Turn off the inflator and open the guide using the supplied Allen key.
  • Replace worn bands with spares from your kit.
  • Contact your supplier for additional parts if required.

Preventive Measures and Best Practices

    • Consult the latest instructions at soku.global/help before each deployment.
    • Regularly check and maintain bands, and blades to prevent downtime.
    • Keep spare parts and tools on-site for quick fixes.
    • Train operators in troubleshooting and document common issues and solutions for future reference.